SG2428P

Kategori :

Deskripsi

FeatureSpecification
Standards and ProtocolsIEEE 802.3i, IEEE 802.3u, IEEE 802.3ab, IEEE802.3z, IEEE 802.3ad, IEEE 802.3x, IEEE 802.3az, IEEE 802.1d, IEEE 802.1s, IEEE 802.1w, IEEE 802.1q, IEEE 802.1p, IEEE 802.1x
Interface24× 10/100/1000 Mbps RJ45 Ports (Auto Negotiation/Auto MDI/MDIX); 4× Gigabit SFP Slots
Network Media10BASE-T: UTP category 3, 4, 5 cable (maximum 100m); 100BASE-TX/1000Base-T: UTP category 5, 5e or above cable (maximum 100m); 1000BASE-X: MMF, SMF
Fan Quantity2
Power Supply100-240V AC, 50/60Hz
PoE Ports (RJ45)Standard: 802.3at/af compliant; PoE+ Ports: 24 Ports; PoE Power Budget: 250 W*
Dimensions (W x D x H)17.3 × 8.7 × 1.73 in (440 × 220 × 44 mm)
MountingRack Mountable
Max. Power ConsumptionV1: 308.6 W (110V/60Hz with 250 W PD connected); 32.1 W (110 V/60 Hz with no PD connected); V2: 294.7 W (220 V/50 Hz) (with 250 W PD connected); V3: 291.9 W (110V/60Hz) (with 250 W PD connected); V4: 306.9 W (110V/60Hz) (with 250 W PD connected)
Max. Heat DissipationV1: 1052.94 BTU/h (with 250 W PD connected); 109.53 BTU/h (with no PD connected); V2: 1005.66 BTU/hr (220V/50 Hz) (with 250 W PD connected); V3: 996.01 BTU/hr (110V/60Hz) (with 250 W PD connected); V4: 1047.30 BTU/hr (110V/60 Hz) (with 250 W PD connected)
Switching Capacity56 Gbps
Packet Forwarding Rate41.7 Mpps
MAC Address TableV1, V2, V4 and above: 8K; V3: 16K
Packet Buffer Memory4.1 Mbit
Jumbo Frame9 KB
Omada AppYes, through Omada Cloud-Based Controller (Not Supported by TL-SG2428P v2); OC300; OC200; Omada Software Controller
Centralized ManagementOmada Cloud-Based Controller (Not Supported by TL-SG2428P v2); Omada Hardware Controller OC300; Omada Hardware Controller OC200; Omada Software Controller
Cloud AccessYes, through Omada Cloud-Based Controller (Not Supported by TL-SG2428P v2); OC300; OC200; Omada Software Controller
Zero-Touch ProvisioningYes. Requiring the use of Omada Cloud-Based Controller (Supported by TL-SG2428P v1, v3 and above, while is not supported by TL-SG2428P v2)
Management FeaturesWeb-based GUI; Command Line Interface (CLI) through telnet; SNMPv1/v2c/v3; SNMP Trap/Inform; RMON (1,2,3,9 groups); SDM Template; DHCP/BOOTP Client; Dual Image, Dual Configuration; CPU Monitoring; Cable Diagnostics; EEE; SNTP; System Log
CertificationCE, FCC, RoHS
Package ContentTL-SG2428P; Power Cord; Installation Guide; Rackmount Kit; Rubber Feet
System RequirementsMicrosoft® Windows® XP, Vista™ or Windows 7/8/10/11, MAC® OS, NetWare®, UNIX® or Linux.
EnvironmentOperating Temperature: 0–50 ℃ (32–122 ℉); Storage Temperature: -40–70 ℃ (-40–158 ℉); Operating Humidity: 10–90% RH non-condensing; Storage Humidity: 5–90% RH non-condensing